Comments on: Calibration Criteria for Analytical Balance https://lab-training.com/calibration-criteria-analytical-balance/ Experience Beyond Books Mon, 05 Sep 2022 04:55:52 +0000 hourly 1 https://wordpress.org/?v=6.7.2 By: Dr. Amit Kumar Rajora https://lab-training.com/calibration-criteria-analytical-balance/#comment-227536 Mon, 05 Sep 2022 04:55:52 +0000 https://lab-training.com/?p=19873#comment-227536 In reply to KAMU VEERABHADRA RAO.

Thanks

]]>
By: KAMU VEERABHADRA RAO https://lab-training.com/calibration-criteria-analytical-balance/#comment-227462 Sat, 03 Sep 2022 06:22:06 +0000 https://lab-training.com/?p=19873#comment-227462 nice

]]>
By: Ratih Nurahmawati https://lab-training.com/calibration-criteria-analytical-balance/#comment-201704 Mon, 06 Jun 2022 09:38:20 +0000 https://lab-training.com/?p=19873#comment-201704 please inform source your Acceptance criteria: the observed weight should be within +/ – 0.1% of the actual value, it is refer to ?

]]>
By: YAKUBREDDY https://lab-training.com/calibration-criteria-analytical-balance/#comment-136953 Wed, 31 Jul 2019 08:18:27 +0000 https://lab-training.com/?p=19873#comment-136953 uncertainty formula and calibration SOP

]]>
By: Pusat Kunci Pintu Rumah Murah Bellezza Idaman https://lab-training.com/calibration-criteria-analytical-balance/#comment-99614 Tue, 16 Oct 2018 16:59:56 +0000 https://lab-training.com/?p=19873#comment-99614 I must thank you for the efforts you have put in penning this site.
I am hoping to check out the same high-grade blog posts by you later on as well.

In fact, your creative writing abilities has inspired
me to get my own, personal blog now ;)

]]>
By: Dr. Deepak Bhanot https://lab-training.com/calibration-criteria-analytical-balance/#comment-91366 Wed, 09 May 2018 11:11:42 +0000 https://lab-training.com/?p=19873#comment-91366 In reply to aly reda.

In such case you have to take the combined uncertainty using the formula given in renowned texts.Add the squares of different uncertainties and take the square root.

]]>
By: aly reda https://lab-training.com/calibration-criteria-analytical-balance/#comment-91213 Sun, 06 May 2018 23:28:56 +0000 https://lab-training.com/?p=19873#comment-91213 thanks for this important article
i have a question, i have certified standard weights like ( 1 -2 -5 -10, ……. gm ) with error and expanded uncertainty and the analytical balance used also have with error and expanded uncertainty for this weights so my question here is how to calculate the acceptance range for each one?

]]>
By: Dr. Deepak Bhanot https://lab-training.com/calibration-criteria-analytical-balance/#comment-73213 Sat, 17 Dec 2016 12:05:40 +0000 https://lab-training.com/?p=19873#comment-73213 In reply to Mohamed Kamal.

Yes. You can obtain standard reference weight set from your national physical laboratory for the purpose of periodic calibration of your weighing balance.

]]>
By: Mohamed Kamal https://lab-training.com/calibration-criteria-analytical-balance/#comment-73158 Fri, 16 Dec 2016 12:07:34 +0000 https://lab-training.com/?p=19873#comment-73158 If that possible to get the reference of the accepted criteria for balance verification.

]]>